INSTALLING A SHUT-OFF VALVE
A shut-off valve should be installed on the discharge port
of the tank to control the air flow out of the tank. The valve
should be located between the tank and the piping system.
Never install a shut-off valve between the compressor pump
and the tank. Personal injury and/or equipment damage
may occur. Never use reducer in discharge piping.
When creating a permanently installed system to distribute
compressed air, find the total length of the system and
select pipe size from the chart. Bury underground lines
below the frost line and avoid pockets where condensation
can gather and freeze.
Apply air pressure to the piping installation and make sure
all joints are free from leaks BEFORE underground lines are
covered. Before putting the compressor into service, find
and repair all leaks in the piping, fittings and connections.
WIRING
All wiring and electrical connections must be performed by
a qualified electrician. Installations must be in accordance
with local and national codes.
Overheating, short circuiting and fire damage will result from
inadequate wiring. Wiring must be installed in accordance with
National Electrical Code and local codes and standards that
have been set up covering electrical apparatus and wiring.
Be certain that adequate wire sizes are used, and that:
1. Service is of adequate ampere rating.
2. The supply line has the same electrical characteristics
(voltage, cycles and phase) as the motor.
3. The line wire is the proper size and that no other equipment
is operated from the same line. The chart below gives
minimum recommended wire sizes for compressor
installations.